How is the weight of steel calculated?
A steel weight calculator multiplies the cross-section area by the length and by the density. Carbon steel is taken as 7,850 kg/m³, so one square meter of 1 mm sheet weighs 7.85 kg. For anything with a constant section, the weight per meter comes first and the length scales it.
For aluminum use 2.70 in place of 7.85, for 304 or 316 stainless about 8.00.
| Shape | Area (mm²) | Weight per meter (steel) |
|---|---|---|
| Plate or flat bar | thickness × width | thickness × width × 0.00785 |
| Round bar | π ÷ 4 × d² | d² × 0.006165 |
| Square bar | a² | a² × 0.00785 |
| Round pipe | π ÷ 4 × (OD² − (OD − 2t)²) | (OD − t) × t × 0.02466 |
| Square or rectangular tube | w × h − (w − 2t)(h − 2t) | area × 0.00785 |
Source: geometry; density 7,850 kg/m³.
What does a 12 mm bar or a 10 mm plate weigh?
A 10 mm plate that is 1,250 mm wide and 2.5 m long weighs 245.3 kg; a 12 m length of 12 mm bar weighs 10.7 kg. The steps for the plate:
- Area: 10 × 1,250 = 12,500 mm².
- Weight per meter: 12,500 × 7.85 ÷ 1,000 = 98.125 kg/m.
- Times 2.5 m: 245.3 kg. In pounds, multiply by 2.2046 (the weight converter does it): about 541 lb.
- At a price of 0.85 per kg the plate costs 208.5.
How much does rebar or TMT weigh per meter?
Rebar weighs its nominal diameter squared divided by 162.2, in kg per meter, when the diameter is in millimeters: a 12 mm bar is 144 ÷ 162.2 = 0.888 kg/m. The divisor is 4,000,000 ÷ (π × 7,850), which is why 162 works as a shortcut on site. Indian TMT bars under IS 1786 are rated on this nominal mass, with sizes from 8 to 50 mm.
| Diameter | kg per meter | Bars per tonne (12 m) |
|---|---|---|
| 8 mm | 0.395 | 211.20 |
| 10 mm | 0.617 | 135.17 |
| 12 mm | 0.888 | 93.87 |
| 16 mm | 1.578 | 52.80 |
| 20 mm | 2.466 | 33.79 |
| 25 mm | 3.853 | 21.63 |
| 28 mm | 4.834 | 17.24 |
| 32 mm | 6.313 | 13.20 |
Source: d² ÷ 162.2; matches the nominal masses listed for IS 1786 bars (8 mm 0.395, 12 mm 0.888, 20 mm 2.466 kg/m).
| Bar | Diameter (in) | lb per ft | kg per m |
|---|---|---|---|
| #3 | 0.375 | 0.376 | 0.560 |
| #4 | 0.500 | 0.668 | 0.994 |
| #5 | 0.625 | 1.043 | 1.552 |
| #6 | 0.750 | 1.502 | 2.235 |
| #7 | 0.875 | 2.044 | 3.042 |
| #8 | 1.000 | 2.670 | 3.973 |
| #9 | 1.128 | 3.400 | 5.060 |
| #10 | 1.270 | 4.303 | 6.404 |
| #11 | 1.410 | 5.313 | 7.907 |
Source: Rebar (Wikipedia), from ASTM A615 nominal sizes.
Real bars are allowed to run a few percent over or under the nominal figure, so a delivery weighed on a scale can differ from the table. The tolerance bands are set in IS 1786 itself; read them there before rejecting a lot on weight.
Which density should you use for stainless steel and aluminum?
Use 7,850 kg/m³ for carbon steel, about 8,000 for 304 and 316 stainless and 2,700 for common aluminum alloys. Stainless grades vary by a few percent, so a mill certificate beats any table.
For painting or coating quotes, the area calculator gives the surface of a sheet or a wall.
What do IPE and W beams weigh?
An IPE 200 weighs 22.4 kg per meter and a W10×49 weighs 49 lb per foot. European IPE sections are named by depth in millimeters; US W shapes carry the nominal depth in inches and the weight in pounds per foot in the name.
| Section | h × b (mm) | Web / flange (mm) | kg per meter |
|---|---|---|---|
| IPE 100 | 100 × 55 | 4.1 / 5.7 | 8.1 |
| IPE 160 | 160 × 82 | 5 / 7.4 | 15.8 |
| IPE 200 | 200 × 100 | 5.6 / 8.5 | 22.4 |
| IPE 240 | 240 × 120 | 6.2 / 9.8 | 30.7 |
| IPE 300 | 300 × 150 | 7.1 / 10.7 | 42.2 |
| IPE 360 | 360 × 170 | 8 / 12.7 | 57.1 |
| IPE 400 | 400 × 180 | 8.6 / 13.5 | 66.3 |
| IPE 500 | 500 × 200 | 10.2 / 16 | 90.7 |
| IPE 600 | 600 × 220 | 12 / 19 | 122.0 |
Source: British Steel, IPE sections data sheet. The calculator lists all 17 sizes from IPE 100 to IPE 600.
| Section | Nominal depth | lb per ft | kg per meter |
|---|---|---|---|
| W8×31 | 8 in | 31 | 46.1 |
| W10×49 | 10 in | 49 | 72.9 |
| W12×40 | 12 in | 40 | 59.5 |
| W14×53 | 14 in | 53 | 78.9 |
| W16×40 | 16 in | 40 | 59.5 |
| W18×50 | 18 in | 50 | 74.4 |
| W21×62 | 21 in | 62 | 92.3 |
| W24×76 | 24 in | 76 | 113.1 |
Source: the weight and depth come from the section name (AISC convention); kg/m = lb/ft × 1.4882. Exact flange and web sizes are in the AISC Shapes Database.
Why does a quoted weight differ from the calculator?
- Mill tolerance. Plate thickness and bar diameter vary within the standard; a plate cut at the minus tolerance weighs less than nominal.
- Corner radii. Square tube has rounded outside corners, and the tool treats corners as sharp, so it reads slightly high.
- Pipe schedule versus wall. Enter the wall thickness from the pipe table, not the schedule number.
- Mixing mm and inches. Switch the unit first, then type; the tool converts what is already in the boxes.
- Galvanizing and paint. Zinc coating adds a few percent for thin sections and is not included.
Comparing suppliers? The unit price calculator puts two quotes on the same per-kg basis, and the length converter turns bar lengths between meters and feet.
Sources
- British Steel: IPE sections, dimensions and properties
- IPE beam (EN 10365 designation)
- Wide-flange beam (W-shape naming)
- Rebar: ASTM A615 bar sizes and masses
- Bureau of Indian Standards: IS 1786 product manual (bar sizes)
- Engineering ToolBox: metal densities
Last reviewed November 17, 2026. Figures are theoretical weights at nominal size, for estimating only; check the mill certificate and the governing standard for orders. The calculator runs in your browser; nothing you enter is sent anywhere. We could not open the IS 1786 mass table itself: the rebar masses on this page are computed with the standard's 7,850 kg/m³ basis and agree with the figures widely quoted for it.