BTU calculator

Air conditioner size in BTU and tons for a room.

Method
ft
ft
ft
Sun
Kitchen
Units

Cooling needed

6,000BTU/h

In tons
–
In kilowatts of cooling
–
Nearest unit to buy
–

    Your room, drawn to scale

    A sizing estimate, not a heat-load calculation. For a whole house or a tricky room ask for an ACCA Manual J calculation.

    How many BTU do you need for a room?

    A BTU calculator turns floor area into cooling capacity: a 150 to 250 square foot room needs about 6,000 BTU per hour on the ENERGY STAR chart. BTU/h is the heat an air conditioner removes in an hour. 12,000 BTU/h is one ton of cooling, which is 3.5 kW, and the chart below assumes an 8 foot ceiling.

    ENERGY STAR room air conditioner sizing chart
    Area (sq ft)m²BTU/hTonskW
    100 to 150 9 to 14 5,000 0.42 1.47
    150 to 250 14 to 23 6,000 0.50 1.76
    250 to 300 23 to 28 7,000 0.58 2.05
    300 to 350 28 to 33 8,000 0.67 2.34
    350 to 400 33 to 37 9,000 0.75 2.64
    400 to 450 37 to 42 10,000 0.83 2.93
    450 to 550 42 to 51 12,000 1.00 3.52
    550 to 700 51 to 65 14,000 1.17 4.10
    700 to 1,000 65 to 93 18,000 1.50 5.28
    1,000 to 1,200 93 to 111 21,000 1.75 6.15
    1,200 to 1,400 111 to 130 23,000 1.92 6.74
    1,400 to 1,500 130 to 139 24,000 2.00 7.03
    1,500 to 2,000 139 to 186 30,000 2.50 8.79
    2,000 to 2,500 186 to 232 34,000 2.83 9.96

    Source: ENERGY STAR room air conditioners buying guidance; metric, tons and kW columns converted by us. Below 100 sq ft the chart has no entry; the tool shows its smallest, 5,000.

    What size AC for a 12 × 15 ft sunny bedroom with two people?

    A 180 square foot sunny bedroom needs about 6,600 BTU/h, so a 7,000 or 8,000 BTU unit. The steps:

    Worked example: 12 × 15 ft, very sunny, two people
    1. Area: 12 × 15 = 180 sq ft. The chart row 150 to 250 gives 6,000 BTU/h.
    2. Very sunny: add 10%, which is 600, giving 6,600.
    3. Two people is the baseline, so nothing is added. No kitchen.
    4. Result: 6,600 BTU/h, 0.55 ton or 1.93 kW. Window units come in steps, so 7,000 is the nearest size up.

    What changes the BTU number?

    Sun, shade, extra people and a kitchen change it, and ENERGY STAR prints a rule for each. The percentage rules apply to the chart value; the fixed amounts are added after.

    Adjustments to the chart value
    ConditionChangeSource
    Room is very sunny +10% ENERGY STAR
    Room is heavily shaded −10% ENERGY STAR
    More than two people regularly +600 BTU/h each extra ENERGY STAR
    Unit is used in a kitchen +4,000 BTU/h ENERGY STAR
    Ceiling above 8 ft scaled by height ÷ 8 our estimate

    Source: ENERGY STAR; the ceiling row is our own proportional rule, because the chart assumes an 8 ft ceiling and gives no figure for taller rooms.

    The chart is for a single room. For several rooms add them up only if they are open to each other; separate rooms each get their own unit. To get the area from a floor plan, the area calculator handles L-shaped rooms and other units.

    What size AC in tons for a room in India or the Gulf?

    Indian retailers say 1 ton for a room up to 120 square feet, 1.5 ton to 180 and 2 ton above that, and one size up for a top floor or a sun-facing wall. That is a different scale from the ENERGY STAR chart, so the tool shows both.

    Retailer tonnage guide (Onida) next to the ENERGY STAR chart
    Room size (sq ft)Retail guideENERGY STAR (BTU/h)
    Up to 120 1 ton (12,000 BTU/h) 5,000
    120 to 180 1.5 ton (18,000) 5,000 to 6,000
    180 to 250 1.5 to 2 ton 6,000
    250 to 350 2 ton (24,000) 7,000 to 8,000

    Source: Onida, how to choose the best AC for your home; ENERGY STAR chart. The retail guide is a retailer's advice, not a standard.

    100 12k 120 12k 150 18k 180 18k 250 24k Room size in sq ft. Grey: ENERGY STAR. Green: India retail guide, thousand BTU/h.
    The tonnage guide runs about 2.4 to 3.4 times the ENERGY STAR chart at these sizes. We found no official source explaining the gap.

    Possible reasons are hotter outdoor design temperatures, roof heat on top floors and nominal tonnage that is higher than delivered capacity. Neither guide is a heat-load calculation, so in a hot climate treat the retail figure as the upper end and ask the installer for the load figure. Running costs matter too: the electricity cost calculator turns a unit's wattage into a monthly bill, and the voltage drop calculator checks that a long cable run to the outdoor unit is thick enough.

    How do BTU, tons and kW relate?

    One ton of cooling is 12,000 BTU/h, which is 3.517 kW of heat removed. This is cooling output, not the electricity the unit draws, which is usually a third or less.

    Common unit sizes
    BTU/hTonskW cooling
    9,000 0.75 ton 2.64
    12,000 1 ton 3.52
    18,000 1.5 ton 5.28
    24,000 2 ton 7.03
    30,000 2.5 ton 8.79
    36,000 3 ton 10.55

    Source: 1 ton = 12,000 BTU/h; 1 kW = 3,412.14 BTU/h.

    How many BTU for a room heater?

    A common rule is 10 watts per square foot of room, with an 8 foot ceiling and decent insulation. That is a rule of thumb from heater makers and dealers, not a standard, and cold regions or poorly insulated rooms need more. One watt is 3.412 BTU/h, so a 1,500 watt heater gives about 5,100 BTU/h.

    Electric heater size by room (rule of thumb)
    RoomWattsBTU/h
    100 sq ft (9 m²) 1,000 3,412
    150 sq ft (14 m²) 1,500 5,118
    200 sq ft (19 m²) 2,000 6,824
    300 sq ft (28 m²) 3,000 10,236

    Source: 10 W per sq ft rule of thumb (not an official figure); 1 W = 3.412 BTU/h.

    What goes wrong when sizing a unit?

    • Choosing by the biggest number. An oversized unit cools the air quickly and stops before it has pulled much moisture out; match the load instead.
    • Counting only floor area. A west window or a roof overhead can matter more than the extra square feet.
    • Mixing capacity and power. 12,000 BTU/h is cooling output; the electrical input is a separate figure on the label.
    • Forgetting units. A 4 × 5 meter room is 215 sq ft, not 20; switch the tool to meters.
    • Treating retail tons as a standard. The two guides above disagree, so say which one you used.

    Sources

    Last reviewed November 17, 2026. Room sizes are worked out on your device and never leave it. The 20 BTU per square foot rule that Energy.gov gives for rooms beyond the chart, and the ceiling and heater figures, are rules of thumb and are labeled as such.